Automatic Charge control function:
1 x By setting the volt-HI:’UP’ volt-LI:’dn’;When the battery voltage is below the volt-LI:’dn’,the relay leads, the charger begins to charge the battery; when the battery voltage is up to volt-HI:’UP’,the relay is disconnected and the automatic charge is completed once;
Charge Time Control Function:
1 x After entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is:–:–h, the default does not turn on time control function;
After the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI’dn’, the charger began to charge the battery, the system began to clock; During the timing, the battery voltage greater or equal to volt-HI’UP’, relay disconnect;
1 x If the OP time is up, the battery voltage is still the lower volt-LI’dn’, the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Press any key to stop flashing;
Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours.